Hitech Central Air Inc. (PTAC Experts) Is a Full Service Heating, ventilation, and Air Conditioning Company with a large Collection of Makes and Models.

Call (718) 577-7875 or Contact Us Online To Schedule Heating and Cooling Services Today!

AIR CONDITIONING SERVICES NEW YORK, BROOKLYN, MANHATTAN

Air conditioner cleaning service near me - Window air conditioner cleaning service near me - Air conditioner cleaning service nyc - in wall air conditioner service - air conditioning steam cleaning - steam cleaning services - Hvac steam cleaning

Hitech Central Air Inc. (PTAC Experts)

HVAC Coil Steam Cleaning New York Queens, Manhattan, Bronx, Brooklyn, Staten Island, Long Island

Residential, Commercial and Industrial Air Duct Cleaning New York

AC Steam Cleaning - HVAC Steam Cleaning and HVAC Chemical Wash Manhattan, Bronx, Queens, Brooklyn, Staten Island, New York City, NYC

air-duct-cleaning-new-york

Hire a professional air conditioner cleaning contractor for all your ac cleaning needs. It is worth hiring a professional air conditioning contractor as you will reap the benefits of a having a good air conditioning cleaning job done. You don't want to have problems with your air conditioning a few months later.

A professional air conditioning cleaner has the expertise and experience to take your project from the start to its completion. He has all the necessary tools to produce a perfect job. He can also give you advice and ideas to help you keep your ac clean.

How can you know you’re getting a fair price for your air conditioner cleaning job? Compare quotes and choose the best price for your project. Enter your ZIP code above to receive free multiple quotes from air conditioning cleaner services in your area. Qualified ac cleaning services will compete for your business, and you can read reviews of their work by homeowners like yourself.

Winterization Maint. Contracts Winter Storage Service Contracts Repair | Service Tune Up AC Steam Cleaning - HVAC Steam Cleaning and HVAC Chemical Wash Manhattan, Bronx, Queens, Brooklyn, Staten Island, New York City, NYC Room AC, Window AC, Thru-the-Wall AC, PTAC Units, Central Air, FCU, WSHP

Mold inside the AC front grille

Step-by-step in shop

AC Steam Cleaning Process ​Air Conditioner is removed and brought to our shop Comprehensive diagnosis is performed on the AC Freon level is checked Drain are checked and cleaned AC is then disassembled completely Coils & parts are steam cleaned with environmentally safe chemicals Reusable air filters are cleaned and foam filters are replaced Fan motor is oiled Necessary components are painted to prevent rust  Air Conditioner is reassembled AC is diagnosed once again to check the final performance and amperage etc... Final delivery and installation is scheduled and performed per your convenience  ​

All air conditioners including PTAC units, Central Air and Room AC, over time are a nesting place for black mold, and their blower wheels as well as their housings make great a place for black mold to accumulate.

Once you notice it on the vent (where the air is pushed out from the unit), or on the coil of the unit it is a warning to get your unit cleaned professionally. As you use your air conditioner or PTAC it removes moisture in the air through the evaporator coil, besides pulling warm air into the unit it pulls microbes and dust particles through it as well. As it does this the water runs down the coil to the base pan where it usually collects on a maintained unit it would drain out to the rear of the unit and then outside.

If the air conditioning unit is not maintained the drains would clog and allow for black mold to develop. It is in these water pools that black mold grows, and then their spores are passed along with the cold air through the ducts into the house. Black Mold is blown out every time an ac with mold is turned on. Blower Wheel Mold and dirt will attach itself on the blower wheel and be pushed out into the room when on. Dirt and mold Dirt and Mold attaches itself to the vent openings of the face. This is blown into the air.

Give us a call to avoid this from happening to you! We will come to your home or business and pick the PTAC or air conditioning unit for transportation to our shop to apply steam cleaning procedure. Once we have the air conditioner in our shop we will per below step-by-step in shop AC Steam Cleaning Process. 

AC Steam Cleaning! HVAC Pressure wash!

Why and when AC steam cleaning is needed? Let's understand step-by-step.

The coils: An air conditioning system has two coils, condenser coil and evaporator coil usually made of copper tubes with aluminum fins. The evaporator coil, or indoor coil, is often described as the "cold" coil because it provides indoor cooling. The coil works by absorbing heat from the indoor air that is blown over by the air handler's fan. The condenser coil or outdoor coil is the "warm" coil as it rejects the heat as a fan blows outside air over the surface. There are variety of coil cleaning solutions to clean both the condenser and evaporator coils.

Dirty Coils Waste Energy and Cost Money: A coil fouled with dirt and grime cannot supply proper heat transfer and results in greater energy consumption. Equipment operating with dirty coils can use up to 37% more energy than those with clean coils. Additionally, a dirty system’s cooling capacity can be reduced by as much as 30%. Dirty coils increase operating pressure and temperatures that breakdown the compressor’s lubricant and can result in equipment failure. A failed compressor means no cooling and costly repair.

Coil Steam Cleaning Frequency: A coil Steam cleaning program should be instituted when the coils are new, clean, and should be performed with a frequency to prevent deterioration of the coils. This can be as often as four times a year (monthly cleaning is reported in some areas). If they do not already exist, install easy to open panels to gain access to the coils. This will make easier access when coil steam cleaning is necessary.

What about the Condensate Pan?:The air drawn across a cooling coil contains water vapor which condenses and collects in a pan under the coil called a condensate pan. The pan is connected to a drain line to keep the pan from overflowing and causing damage to the air handler or other building structures. As it is generally wet, microorganisms can form colonies in the condensate pan. Cleaning the condensate pan and checking for proper drainage is an important part of the coil cleaning process.To help prevent growth of these organisms, the pan should be treated between cleanings with a biocide. 

Solution: Hitech Central Air Inc. (PTAC Experts) has the solution. We offer a comprehensive AC steam cleaning, Air Conditioner Steam Cleaning and pressure wash for a variety of different HVAC systems. AC steam cleaning is the only effective absolute remedy. Please contact us for more information on pricing and services related to Steam Cleaning Process.

RULE OF THUMB: AC Steam cleaning is recommended for every air conditioner at least every 3-4 years to keep the good indoor air quality. Call Hitech Central Air Inc. (PTAC Experts) at (718) 577-7875 for 

Air Conditioner Steam Cleaning, AC Steam Cleaning, Central System Steam Cleaning, Condensing Unit Steam Cleaning, Air Handler Steam Cleaning, Mini Split Steam Cleaning in Manhattan, Bronx, Queens, Brooklyn, Staten Island, New York, NYC

Top Cities Covered by our Air Conditioner Cleaning Contractors:
New York | Brooklyn | Bronx | Manhattan | Queens